Chat with us, powered by LiveChat

Meet the 2030 CARB deadline and save millions with CREST

California's Air Resources Board (CARB) regulates your fleet's average refrigerant impact, so where you convert matters more than what you convert. Deep conversions at the right stores of A2L refrigerants such as R-454C or natural-refrigerant CO₂ create enough headroom for other machine rooms to fall off your conversion list entirely.

The Commercial Refrigeration Energy Savings and Training (CREST) program funds these deep conversions and bundles energy efficiency into one managed project.

≈3× the compliance progress

One high-GWP store deep conversion moves your fleet average as far as three mid-GWP conversions.

Two funded paths

A2L (e.g. R-454A/C) or natural-refrigerant CO₂ (R-744) both qualify for substantial CREST incentives.

Energy savings bundled in

Case doors and other deemed measures cut refrigeration energy 20–40%.

The fleet math

Every store pulls your fleet average
up or down. Convert where it counts.

By 2030, chains with 20 or more California stores must achieve a fleet weighted-average refrigerant GWP of less than 1,400. That average rewards a small number of deep conversions over many shallow ones.

New to GWP?

  • GWP (global warming potential) is a refrigerant’s climate-impact score, how much warming a pound of it causes if it leaks, compared to a pound of CO₂. R-404A scores about 3,900. R-454C scores 148; CO₂ itself scores 1.
  • California doesn’t regulate individual stores, it regulates your fleet’s average. Every store’s refrigerant pulls that average up or down. A store on R-454C sits ~1,250 points below the 1,400 line, and a store on CO₂ about 1,400 below. A store on R-448A sits just 13 points below it, compliant on its own, but contributing almost nothing toward the target.

1 deep conversion ≈ 3 mid-GWP conversions

Converting one high-GWP store deep to R-454C or CO₂ moves your fleet average roughly as far as converting one high-GWP store and two R-407A stores, so each deep conversion can take other machine rooms off your list.

≈ 95× the headroom of an R-448A conversion

A store on R-448A lands 13 points under the threshold, a deep conversion lands well over 1,200 under. Deep conversions create room for the rest of the fleet.

Your options

Three paths to compliance.

Self-funded R-448A is the path most stores are already on. The two deep conversion paths both qualify for substantial CREST incentives. Both create fleet headroom that lets you convert fewer stores overall, saving millions of dollars of compliance investment as well as energy efficiency savings.

Self-Funded

R-448A

Lower-GWP HFC blend

Your own capital

  • Non-flammable (A1), broadly drop-in compatible.
  • High percentage of stores must be converted.

What to know

Lands the fleet at GWP 1,387, just 13 points under the threshold, so nearly every store must be converted. Does not qualify for utility incentives.

CREST-Funded

A2L

Very-low-GWP e.g. R-454C, R-454A, R-455A

Funded — lowest project cost

  • Improves on R-404A efficiency; near-drop-in conversion.
  • Low GWP, compliant beyond 2030.
  • Significant incentive; fastest.

What to know

Mildly flammable (A2L), requires machine-room ventilation and permitting.

CREST-Funded

CO₂ Transcritical

Natural refrigerant (R-744)

Funded — premium natural refrigerant

  • Natural refrigerant, non-flammable, no fluorinated chemicals.
  • GWP 1, future-proof.
  • Leading California grocers already moving to CO₂.

What to know

Full system replacement, incentive contributes to capital cost.

Choosing between the funded paths

A2L or CO₂? It comes down to fit.

Both A2L and CO₂ refrigerant conversions qualify for incentives. Both create the headroom that secures your fleet, and both clear 2030 with room to spare. The right choice depends on your capital plan, your refrigeration strategy, and how you weigh permanence.

Consideration
A2L Refrigerants
CO₂ Transcritical
Capital & disruption
Lower capital; converts your existing rack with less disruption.
Higher capital; full system replacement.
Refrigerant type
Mildly flammable; requires machine-room ventilation and permitting.
Non-flammable natural refrigerant; no fluorinated chemicals.
Performance
Proven, more efficient than R-404A.
Efficient, engineered for SoCal climate.
Compliance horizon
Compliant beyond current regulatory limits.
Longest compliance horizon.
Best fit when…
You want the fastest, lowest-cost path using your existing equipment.
You want certainty into the 2030s and beyond.

The Math

One project, three benefits.

The value of a deep conversion isn’t just the incentive on that store, it’s the machine rooms elsewhere in the fleet that no longer need converting, and the energy savings that continue every year.

At the converted store

A funded project

Paid directly to you and capped at project cost. For an A2L conversion, that can add up to no out-of-pocket cost or significantly reduce the net cost of CO₂ replacement projects. 

Across the fleet

Feed two birds with one scone

Mid-GWP conversions (e.g. to R-448A) are expensive and come out of your own capital. On average, each deep conversion can alleviate two of those projects. 

Every year after

20–40% refrigeration energy savings

Refrigerated case doors and other measures are included in the project, reducing HVAC and compressor load, saving roughly $60,000 a year at a typical store.

Energy savings from case doors and other projects can be achieved at other stores in the fleet, including those that are not converting to low GWP refrigerant.

The Refrigerant Incentive

Incredible incentives.

Both funded conversion paths go beyond standard refrigerant practice, which is what makes the incentives so large. Incentives are calculated based on the greenhouse-gas emissions avoided by converting away from your existing high-GWP refrigerant. The higher the GWP of the refrigerant you’re replacing, the higher the incentive.

Your current refrigerant
Convert to A2L
Convert to CO₂
Rates and per-store figures are approximate and based on a nominal 3,000 lb existing system charge. Incentives capped at 50%-75% of project cost; actual incentives will be confirmed after site-specific assessment. Stores with newer equipment may qualify for higher incentives.
R-404A
GWP 3,922 · highest available rate
~$187 / lb
~$562,000 per store
~$194 / lb
~$584,000 per store
R-407A
GWP 2,107 · common in older racks
~$131 / lb
~$394,000 per store
~$141 / lb
~$423,000 per store
Other high-GWP
R-507A, R-408A, R-422D and similar
site-specific
site-specific

One Managed Project, Per Store

Whichever refrigerant you choose, it's one project.

The conversion comes bundled with energy efficiency, a system tune-up, and any qualifying capital upgrades all scoped, designed, installed, and verified by Cascade Energy and our trade partners. 

Low-GWP refrigerant conversion

We convert your system to an A2L refrigerant or CO₂ including leak detection, controls, and full commissioning. The largest part of your store's climate footprint, handled end to end.

Energy efficiency upgrades

Display-case doors, heat-pump water heating and more. Deemed rebates across refrigeration, water heating, food service, HVAC, and lighting.

System tune-up

We optimize controls, charge, and setpoints so your refrigeration runs at peak efficiency from the day the project closes.

Capital improvements

Roll qualifying equipment upgrades into the same managed project and schedule.

The Regulatory Backdrop

The California Cooling Act

Both tracks are designed to keep your fleet compliant with SB-1013 into the 2030s.

2025

Virgin high-GWP supply restricted

California restricts the sale of virgin R-404A, R-407A and similar high-GWP refrigerants. Stores on these now depend on reclaimed supply.

2026

SB-1013 Phase 1

Chains with 20+ California stores must reach a company-wide weighted-average GWP of ≤2,500, or a 25% reduction in HFC emissions by Jan 1, 2026.

2030

SB-1013 Phase 2

The fleet average must fall to ≤1,400 by Jan 1, 2030.

Energy Efficiency · Deemed Rebates

Fast, fixed rebates.

Deemed rebates pay a set amount per unit installed based on pre-defined criteria. These bundle into the same managed project as your refrigerant conversion.

The Refrigerant Incentive

Refrigeration · SWCR015

Case door retrofit

Add doors to open vertical display cases to cut heat infiltration and compressor run time.

~$450 / ft

per linear foot of case

Refrigeration · SWCR019

Coffin-to-reach-in

Replace open-top horizontal freezer coffins with vertical glass-door reach-ins. Increases merchandised volume ~20%.

$108–$170 / ft

per linear foot of original coffin case

Refrigeration · SWCR021

Open case replacement

Replace open multi-deck cases with enclosed glass-door reach-ins with ECM fan motors and LED lighting.

$360–$554 / ft

per linear foot of new case

Water Heating, Food Service & More

Water heating · SWWH028

Large heat-pump water heater

Replace gas water heaters with a high-efficiency commercial HPWH (≥75 gal, COP/UEF ≥3.0). Top rebate tier for grocery.

$9,000–$23,000

per unit (80–120 gal, grocery)

Water heating · SWWH027

Commercial heat-pump water heater

Replace a 45–100 gal gas water heater with a qualifying electric HPWH.

$12,000–$25,000

per unit (grocery, varies by size)

Food service · HVAC · lighting

Kitchen, motors & lighting

Combination/convection ovens, electric fryers, refrigerated prep tables, switch-reluctance motors, packaged heat pumps, LED.

$1,800–$5,600

per unit · measures vary by type

Most measures must be installed and commissioned by December 31, 2029. Exception: heat-pump water heaters (SWWH027/SWWH028) must be installed by October 7, 2026. Full specifications are in the CREST Deemed Rebate Catalog — email crest@cascadeenergy.com for a copy.

How it Works

From fleet assessment to verified savings.

We assess the fleet, then the stores. From there, efficiency measures and refrigerant conversions run on timelines tailored to meet your requirements.

Step 1: Fleet & site assessment

We model your fleet’s refrigerant mix and charge to identify which stores create the most headroom per dollar, recommend A2L or CO₂ for each candidate, then scope the store — eligible measures, refrigerant inventory, system charge, and machine-room fit. No cost, no obligation at this stage.

Deemed Rebates

≈ 22–30 months

Step 2: Application

We prepare the rebate application and reservation; you review and sign.

2–4 weeks

Step 3: Installation

Your contractor installs the measures.

2–3 months

Step 4: Processing & Rebate

We submit the application to your utility and handle the follow-up.

Paid 8–12 weeks after approval

Refrigerant conversion (NMEC)

≈ 22–30 months

Step 2: Project Development & Approval

Feasibility study, program disposition, then your incentive reservation.

4–6 months

Step 3: Tune-Up & Installation

A one-day tune-up triggers a milestone payment; your contractor then performs the conversion and other energy efficiency projects.

4–6 months install

Step 4: Verification & Payment

50% of the incentive is paid after completed installation; the remaining 50% after a 12-month measurement period.

Final payment ≈ 3 months after M&V closes

See what the fleet math says for your stores.

Share your store list and refrigerant inventory, and we’ll model your fleet average, identify the highest-leverage conversions, and come back with a store-by-store recommendation on fit, incentives, and savings.